Quick answer: Sealant (often called mastic) is failing if it's cracked, hard or brittle, pulling away from either side of the joint (adhesive failure), splitting down the middle (cohesive failure), missing, sagging, chalky or heavily stained, or if you're getting leaks or draughts around windows and panels. Most façade sealants last around 10–20 years. If yours is near that age, or shows two or more of these signs, plan a close inspection and re-sealing before it starts letting water in.
The 7 warning signs
| # | Sign | What it means | Action |
|---|---|---|---|
| 1 | Pulling away from one side (a gap between sealant and frame or stone) | Adhesive failure: poor prep, wrong primer, or excess movement | Re-seal. Water can enter directly. |
| 2 | Splitting down the middle | Cohesive failure: the joint moves more than the sealant can take, or the sealant has aged | Re-seal, possibly with a higher-movement sealant or a re-designed joint |
| 3 | Hard, brittle, crazed surface | Ageing and UV damage; the sealant has lost its elasticity | Plan replacement |
| 4 | Gaps, missing sections, or sealant eaten by birds | Mechanical damage or total failure | Re-seal urgently on weather faces |
| 5 | Dirty streaks or staining alongside joints | Plasticisers migrating from some sealants, or water tracking | Check the sealant type; may need replacement with a non-staining product |
| 6 | Sagging, bulging or soft and sticky | Wrong product, or the sealant was applied too deep without a backer rod | Replace correctly |
| 7 | Leaks or draughts at window perimeters | Often a sealant failure, though not always (see leak investigation) | Investigate, then re-seal |
Rule of thumb: a correctly designed movement joint has sealant bonded to two sides only, with a backer rod behind it. If you see sealant smeared over the surface or packed deep into the joint, it was probably installed incorrectly and will fail early.
Why sealant matters more than its cost
Sealant is one of the cheapest parts of a façade and one of the most important. When it fails:
- water gets in, damaging insulation, fixings and interiors;
- air leaks raise heating and cooling costs;
- wet fixings corrode, which matters most for stone and cladding.
Replacing sealant on schedule is far cheaper than repairing what water damages.
How to check from the ground (and why it isn't enough)
From inside or at ground level, look for gaps, staining and leaks. Upper-floor joints need close access, because many failures look fine from 20 m away. During a rope access inspection, technicians press and probe the sealant to check adhesion and elasticity. That's the only reliable way to tell.
What happens when it's re-sealed
- Cut out all old sealant and backer rod.
- Clean and prepare the joint faces, removing residues.
- Prime where the manufacturer requires it.
- Insert a new backer rod at the correct depth.
- Apply sealant chosen for the substrate and the joint movement, following BS 6213 guidance and the manufacturer's instructions.
- Tool it to the correct profile.
- Record with photos, and water-test if the job was a leak repair.
Weather matters: most sealants need dry joints and temperatures above about 5 °C, so plan major re-sealing for spring to autumn. For the technical reasons joints fail, see why external sealant joints fail.
FAQ
How long does façade sealant last?
Typically 10–20 years, depending on the product, joint design, workmanship and exposure. South- and west-facing elevations usually age fastest.
Can you seal over old mastic?
No. Sealing over failed sealant traps the problem and won't bond properly. Old sealant must be cut out.
How much does re-sealing cost?
It's usually priced per linear metre, or by the day for scattered repairs. A fixed price should follow a site survey.
Get your sealant checked
We inspect, report and re-seal by rope access, with no scaffold needed. See our building maintenance and services, or request a site survey.
Sources
- BS 6213:2000+A1:2010, Selection of construction sealants: guide.
- ISO 11600, Building construction: jointing products: classification and requirements for sealants.