Quick answer: Water that gets into a façade follows gravity and the building's hidden paths: along cavity trays, down curtain-wall mullions and transoms, across lintels, along steel frames and through service penetrations. So a damp patch at a level 5 window head may be caused by a failed coping at roof level, an open joint two bays across, or a blocked drainage slot above. That's why re-sealing the nearest joint often doesn't work, and why proper diagnosis traces the path back from the symptom to the source.
How water moves inside a façade
``` Entry point (e.g. failed coping joint) │ ▼ Into cavity / behind cladding │ ├──► runs along cavity tray ──► exits at a gap in the tray end (stop end missing) │ ├──► tracks down mullion/transom ──► appears at a window head floors below │ └──► follows steel or fixings ──► appears at a ceiling away from the façade ```
Six common entry routes
| # | Entry route | Where water often appears |
|---|---|---|
| 1 | Parapet & coping joints, failed cappings | Top-floor ceilings and window heads, sometimes several floors down |
| 2 | Failed perimeter sealant at windows and panels | Window reveals, sills, nearby walls |
| 3 | Curtain-wall gaskets & blocked drainage slots | Transoms and sills, often below the actual entry |
| 4 | Missing or failed cavity trays and stop ends | Above lintels, at the edges of openings |
| 5 | Penetrations: balustrade fixings, signage brackets, vents, cables | Unrelated-looking spots inside |
| 6 | Roof/wall junctions & flashings | Top-floor walls and corners |
How to trace it
- Leak diary: match leaks to rain intensity and wind direction (see façade leak investigation).
- Internal mapping: moisture readings and thermal imaging to see how far water spreads inside.
- Work upward and to windward from the symptom on the façade, looking for likely entry points.
- Close-access inspection of candidates: joints, gaskets, copings, penetrations.
- Water test one candidate at a time, bottom-up, with someone watching inside, until the leak is reproduced.
- Repair and re-test.
Clues that point to a remote source
- Delay: the leak appears hours after rain starts, or after it stops, which suggests water is travelling.
- Wind dependence: only in rain from one direction, which points to entry on that elevation's exposed side.
- Multiple symptoms in a vertical line, which suggests a source at the top of that line.
- "Fixed" leaks that come back after local sealing.
FAQ
Can thermal imaging find the leak?
It can show where moisture is inside the building, which helps narrow the search, but it rarely pinpoints the external entry point alone.
Why did my sealant repair not stop the leak?
Because the water probably wasn't entering there. Without a confirmed entry point, local repairs are guesswork.
Who should investigate complex leaks?
A combination of close access (rope access), testing and, for system or design problems, a façade engineer.
Trace your leak properly
See our waterproofing and services, or request a site survey.
Sources
- BS EN 13051 (curtain walling site water test).
- BRE guidance on rain penetration and cavity trays.