24/7 Emergency Rope Access 07469 343612

Masonry Paint Types: Acrylic, Mineral, Elastomeric and More

Acrylic, mineral (silicate), elastomeric, siloxane and anti-carbonation coatings compared: breathability, flexibility and where each is best used.

Quick answer: Exterior coatings differ in how breathable, flexible, water-repellent and durable they are, and the right one depends on the surface and its condition. Acrylic masonry paint is the common, general-purpose choice for sound render and concrete. Mineral (silicate) paint bonds chemically to mineral surfaces and is very breathable, so it suits traditional masonry and lime-based walls. Elastomeric coatings are thick and flexible and can bridge hairline cracks, but they can trap moisture if used on a damp wall. Siloxane-modified paints repel water while staying breathable. Anti-carbonation coatings protect reinforced concrete. Always check the data sheet and compatibility with what is already on the wall.

What to look for in an exterior coating

PropertyWhy it matters
Breathability (vapour permeability)Lets moisture escape from the wall. Poor breathability can trap moisture and cause blistering
Water repellencyReduces how much rain soaks into the surface
FlexibilityCopes with movement and can bridge fine cracks
AdhesionBonds to the surface, and to existing coatings where applicable
Durability and colour retentionAffects how long it looks good and protects
Resistance to algae and dirtHelps it stay cleaner for longer
AppearanceFinish, colour range and texture

No coating is best at everything. The trade-offs are the point.

The main types

TypeCharacteristicsBest forWatch out for
Acrylic masonry paintWater-based, film-forming, wide colour range and good durability. Moderately breathableSound render, concrete and brick in good conditionCan trap moisture on damp or traditional walls, and may peel if applied to poorly prepared surfaces
Mineral (silicate) paintReacts chemically with mineral surfaces, very breathable, matt finishLime render, traditional masonry, and suitable mineral substratesNeeds suitable surfaces, careful preparation and skilled application. Colour range can be more limited
Elastomeric coatingThick, flexible film that can bridge hairline cracks and resists waterCracked but sound render and concrete where flexibility helpsCan trap moisture. Does not fix structural or wide cracks. Must not be applied over a wet or salty wall
Siloxane-modified paintWater-repellent but breathableMasonry that needs to shed water and let vapour outCheck the data sheet for suitability on the particular surface
Anti-carbonation coatingForms a barrier against carbon dioxide while allowing moisture vapour to passReinforced concrete that needs protection against corrosionDoes not repair existing corrosion. Use as part of a repair system
Lime wash and lime paintsTraditional, very breathable, soft finishHistoric buildings and lime-based surfacesNeeds reapplication. Check suitability. See listed buildings and conservation areas
Textured coatingsThick coatings with a textured finishHiding minor surface imperfectionsCan hold dirt, and can be hard to remove

Matching coating to surface

SurfaceUsually suited to
Cement render, sound and dryAcrylic masonry paint, siloxane paint or elastomeric where cracking is a concern
Lime render and traditional masonryMineral paint or lime-based paint
Concrete (reinforced)Anti-carbonation or protective coatings, often as part of a repair system. See concrete cracks and spalling
BrickOften best left unpainted. If painted, breathable products only
Previously painted surfacesA coating compatible with the existing one, after proper preparation
Metal and claddingSpecialist systems, following the manufacturer's advice

Compatibility with existing coatings

A new coating that does not get on with the old one will fail. Typical problems include:

  • Mineral paint over an old film-forming coating, which will not bond properly
  • A flexible coating over a loose or powdery surface
  • Solvent-based products on weak substrates
  • Overpainting products that contain additives that bleed through

When in doubt, test a small area and let it cure and weather before committing to the whole building. See external repainting: preparation, timing and what to ask.

Preparation matters more than the product

The best coating will fail on a poorly prepared wall. Typically:

  1. Find and fix any water entry, since moisture will lift any coating. See façade waterproofing coatings: when they work
  2. Repair cracks and failed areas
  3. Remove loose and failed paint
  4. Clean and treat growth. See algae, moss and biological growth
  5. Allow the wall to dry to the level the data sheet requires
  6. Prime or stabilise where required
  7. Apply in suitable weather

Weather

Coatings need suitable temperature and humidity and dry surfaces. As a guide, generally above 5 °C and with the surface at least about 3 °C above the dew point, but the data sheet sets the limits.

Questions to ask a contractor

  • Which coating do you propose, and why is it suited to this surface?
  • Is it breathable enough for this wall?
  • Is it compatible with the existing coating?
  • What preparation is included?
  • How many coats, and at what coverage?
  • What does the warranty cover?
  • Will you do a test area first?

FAQ

Which is the best masonry paint?

There is no single best. It depends on the surface, its condition and what you need the coating to do.

Can elastomeric coating stop cracks?

It can bridge fine, stable cracks. It will not fix wide cracks or movement, and it can trap moisture on damp walls.

Why does paint peel off render?

Usually because of damp, poor preparation, or incompatibility with what was there before.

How long does it last?

It varies with the product, preparation and exposure. Check the manufacturer's guidance.

Talk to us

If you are planning to repaint, send us the address and photographs of the walls. We will tell you what we can see and what preparation is likely to be needed. Read about our external painting service, or request a site survey.

Sources

  • Manufacturer technical data sheets for the coatings (vapour permeability, application limits, compatibility).
  • BS 6150, Painting of buildings: code of practice. Check the current edition.
  • BS EN 1504, Products and systems for the protection and repair of concrete structures. Check the current editions.
Keep reading

More guides

When Is Rope Access the Right Choice for High-Level Building Work?

Is rope access right for your job? A task-by-task guide to what it does well, where it struggles and when scaffold or a MEWP is better.

Read the guide →

When Should a Building's Anchor Provision Be Reviewed?

Beyond the annual BS 7883 inspection, seven situations mean your roof anchors need reviewing, such as refurbishment, new plant and missing records.

Read the guide →

When Cleaning Is Not Enough: Signs a Façade Needs Repair

A façade clean often uncovers defects the dirt was hiding: cracks, open joints, failed sealant, rust and spalling. What each means and what to do next.

Read the guide →
Planning work at height?

Need help with your building? Talk to our team.