Quick answer: A proper commercial façade inspection should include a close-access visual inspection of every agreed drop (within arm's reach, not just binoculars); tap testing of stone, render, tiles and concrete for hollow or loose areas; checks of fixings, cramps and brackets where visible; sealant and gasket condition; glazing, copings, parapets and flashings; drainage (drips, weep holes, gutters); and any attachments such as signage and bird netting. You should receive a photo-referenced defect report with locations, urgency ratings and recommendations, and anything dangerous should be made safe on the day.
The inspection checklist
| Element | What's checked | How |
|---|---|---|
| Stone, brick, terracotta | Cracks, spalls, loose units, open joints, failed pointing, displaced pieces | Visual + tap test with a hammer |
| Render | Cracking, hollow areas, debonding, bulges | Tap test, visual |
| Concrete | Spalling, exposed or rusting reinforcement, rust staining | Visual + tap test; cover meter if specified |
| Metal cladding | Coating breakdown, corrosion, loose panels, missing fixings | Visual, hand check |
| Glazing / curtain walling | Cracked glass, failed or misted units, gasket shrinkage, pressure-plate and cap fixings | Visual, hand check |
| Sealant joints | Cracking, hardening, loss of adhesion, gaps | Visual + hand/probe check |
| Copings, parapets, cornices | Open joints, rocking stones, failed cappings, vegetation | Hand check, tap test |
| Flashings & roof-wall junctions | Lifted lead, open laps, failed upstands | Visual, hand check |
| Drainage | Blocked drips, weep holes, curtain-wall drainage slots, gutters | Visual |
| Attachments | Signage brackets, lighting, CCTV, aerials, bird netting, redundant fixings | Hand check |
| Access equipment | Anchors, davits, BMU tracks (condition only; certification is separate) | Visual; check certificate dates |
Why "close access" matters
From the ground or a drone you can spot obvious problems, but you can't tap-test stone, feel a loose cramp, test sealant adhesion or remove a loose fragment. Close-access inspection by rope access puts a technician at arm's length from every point on each drop. It's also the only method that can make safe on the spot, for example by removing loose material that would otherwise be a hazard to the pavement.
What the report should contain
- Summary: overall condition and the top priorities.
- Scope and limitations: which drops were inspected, what wasn't accessible, and the weather on the day.
- Defect schedule: each defect with a reference number, location (elevation, level, drop), photo, description, urgency rating and recommended action.
- Make-safe record: what was removed or secured on the day.
- Marked-up elevations showing where each defect is.
- Recommendations: repairs, further investigation, specialist input, and when to inspect next.
See what should be in a high-level condition report for a full template.
How long does it take?
That depends on the number of drops and the façade type. How many drops a team covers in a day depends on the façade and the detail needed, and ornate stonework takes longer. The contractor should confirm the time on site and when the report will follow.
FAQ
How often should a façade be inspected?
A common approach is annual visual checks, plus a close-access inspection every five years, with shorter cycles for older, taller or stone and concrete buildings. See how often to inspect a commercial building exterior.
Is tap testing safe for the façade?
Yes. It's done with a light hammer to listen for hollow sounds, and it's a standard technique for finding loose material before it falls.
Can repairs be done during the inspection?
Small make-safes, yes. Planned repairs are better scoped from the report and done in a follow-up visit, unless agreed in advance.
Who should interpret the findings?
The inspection records the condition. Defects that suggest structural or system problems should go to a structural or façade engineer.
Book a façade inspection
Send the address and any concerns. See our building maintenance and rope access in London, or request a site survey.
Sources
- Occupiers' Liability Acts 1957 and 1984 (duty of care to people near the building).
- BS 8210:2020, Facilities maintenance management: code of practice.